manualshive.com logo in svg
background image

RadioLINK

RELAY BASE

Instruction Manual

Contains vital information on the product’s operation and 
installation. Read and retain carefully. If you are just installing 
this product 

the manual MUST be given to the householder

.

1. Introduction

The Ei428 RadioLINK Relay Module is a device that switches 
a relay upon receipt of an alarm signal from a suitable Ei 
Alarm. The electrically isolated contacts can be used for many 
applications such as signalling, turning on lights, etc.  The 
Ei428 is designed to operate with Ei RF devices.

The Ei428 RadioLINK Relay Module is powered by the 
230VAC mains and has rechargeable back-up cells. As 
supplied the relay operates continuously (i.e. it switches when 
one of the Alarms detects fire and switches back when the 
alarm condition is finished).

2. Installation

WARNING

:  Mains powered Ei428 RadioLINK Relay modules  

should be installed by a qualified electrician in accordance 
with the Regulations for Electrical Installations published 
by the Institution of Electrical Engineers (UK) (i.e. BS7671) 
Failure to install the unit correctly may expose the user 
to shock or fire hazards. This unit is not waterproof and 
must not be exposed to dripping or splashing. T

he Ei428 

must  only be installed in a building installation where 
an appropriate disconnect device has been fitted (i.e. 
all-pole mains switch).

1.  Choose a suitable mounting position near the mains supply 

and the device to be connected to the relay. Keep it away 
from metal surfaces or large metal objects (e.g. water 
cylinder, fuse boards) which can reduce the RF signal range. 

 
2.  Disconnect the AC mains supply from the circuit that is 

going to be used.

3.  Where the incoming wiring is on the surface of the wall/ 

ceiling, the appropriately sized trunking / conduit must be 
chosen to mate with the unit. Use a sharp knife to remove 
the material from the knockout, making sure that there is no 
gap when mated with trunking/conduit. There is one suitable    
surface cabling knockout (the other two surface entries are 
not recommended as the wiring will reduce the antenna 
signal). There is one rear entry knockout. See figure 1b.

4.  Screw the Ei428 module to the wall after first removing the 

required knockout and bringing the house wires through it 
(see figure 1b).

1

Model: Ei428

Содержание RadioLINK Relay Module Ei428

Страница 1: ...7671 Failure to install the unit correctly may expose the user to shock or fire hazards This unit is not waterproof and must not be exposed to dripping or splashing The Ei428 must only be installed in a building installation where an appropriate disconnect device has been fitted i e all pole mains switch 1 Choose a suitable mounting position near the mains supply and the device to be connected to ...

Страница 2: ...he mains power is connected or the rechargeable cells are activated With the switch in the C position the alarm signal will switch the latching relay until it receives a cancel signal 7 Connect the rechargeable cells by carefully and gently sliding the switch to the ON position see figure 1b This switch must be in the on position to ensure correct operation 2 HOUSE CODE SWITCH INDICATOR LIGHT GREE...

Страница 3: ...esult in 4 flashes It may take up to 10 minutes before all 4 flashes are seen The flash pattern will repeat every 5 to 10 seconds while the Ei428 remains in house code mode If it fails to flash the correct number of times then consult the Troubleshooting section of this instruction manual To complete the commissioning the RF system must exit House Code mode 13 The Ei428 will automatically exit Hou...

Страница 4: ...ck that all detectors relays are communicating in their final installed positions If units are rotated and or resited we recommend that all units are returned to the factory settings press and hold the house code switch on for about 6 seconds until the relevant light comes on and then flashes slowly Then house code all units again in their final positions as indicated above The RadioLink interconn...

Страница 5: ...elay should become defective within the guarantee period it must be returned to where it was purchased or alternatively to Ei Electronics carefully packaged with the problem clearly stated see section 5 Getting your Relay Base Serviced along with proof of the date of purchase We shall at our discretion repair or replace the faulty unit 7 Technical Specification Mains 230 VAC 40mA 50HZ 0 8W Mains I...

Страница 6: ...ources of interference preventing communication The radio paths may be disrupted by moving furniture or renovations and so regular testing protects against these and other faults ii Receivers may be blocked by radio signals occurring on or near their operating frequencies regardless of the house coding This equipment generates uses and can radiate radio frequency energy and if not installed and us...

Страница 7: ...m other waste streams to ensure that it can be recycled in an environmentally sound manner For more details on collection and proper disposal please contact your local government office or the retailer where you purchased this product Hereby Ei Electronics declares that this Ei428 RadioLINK Relay Base is in compliance with the essential requirements and other relevant provisions of Directive 2014 ...

Страница 8: ...s 2020 Aico Ltd Mile End Business Park Maesbury Road Oswestry Shropshire SY10 8NR U K Tel 01691 664100 www aico co uk Ei Electronics Shannon Industrial Estate Shannon Co Clare Ireland Telephone 353 61 471277 www eielectronics com 8 ...

Отзывы: