Service Manual for
RCO Speed Oven
42
#
NAME
DESCRIPTION
SETTING DEF SETTING/RANGE
C6-03 Carrier Frequency
Upper Limit
Sets the upper limit for the carrier
frequency.
10.0
10.0
1.0 to 15.0 kHz
C6-04 Carrier Frequency
Lower Limit
Sets the lower limit for the carrier
frequency.
10.0
10.0
1.0 to 15.0 kHz
C6-05 Carrier Frequency
Proportional Gain
Sets the relationship of output
frequency to carrier frequency
when C6-02 = F.
0
0
00 to 99
References
d1-01 Frequency
Reference 1
Frequency reference
15.00
0.00
0.0 Hz to 400.00 Hz
d1-02 Frequency
Reference 2
Frequency reference when digital
input “Multi-Step Speed Reference
1” (H1-XX = 3) is on.
30.00
0.00
d1-03 Frequency
Reference 3
Frequency reference when digital
input “Multi-Step Speed Reference
2” (H1-XX = 4) is on.
57.15
0.00
d1-04 Frequency
Reference 4
Frequency reference when
digital inputs “Multi-Step Speed
Reference 1, 2” (H1-XX = 3 and 4)
are on.
0.00
0.00
d1-05 Frequency
Reference 5
Frequency reference when digital
input “Multi-Step Speed Reference
3” (H1-XX = 5) is on.
0.00
0.00
d1-06 Frequency
Reference 6
Frequency reference when
digital inputs “Multi-Step Speed
Reference 1, 3” (H1-XX = 3 and 5)
are on.
0.00
0.00
d1-07 Frequency
Reference 7
Frequency reference when
digital inputs “Multi-Step Speed
Reference 2, 3” (H1-XX = 4 and 5)
are on.
0.00
0.00
d1-08 Frequency
Reference 8
Frequency reference when multi-
function input “Multi-Step Speed
Reference 1, 2, 3” (H1-XX = 3, 4,
5) are on.
0.00
0.00
d1-17 Jog Frequency
Reference
Frequency reference when digital
inputs “Jog Frequency Reference”,
“Forward Jog”, or “Reverse Jog”
are on.
6.00
6.00
d2-01
Frequency
Reference Upper
Limit
Sets the frequency reference upper
limit as a percentage of maximum
output frequency (E1-04).
92.0
100.0 0.0% to 110.0%
d2-02
Frequency
Reference Lower
Limit
Sets the frequency reference lower
limit as a percentage of maximum
output frequency (E1-04).
0.0
0.0
0.0% to 110.0%
d3-01 Jump Frequency
1
d3-01 to d3-04 allow programming
of three prohibited frequency
resonance points for eliminating
problems with resonant vibration of
the motor/machine.
0.0
0.0
0.0 to 400.0 Hz
d3-02 Jump Frequency
2
0.0
0.0
d3-04 Jump Frequency
Width
This parameter sets the dead-
band width around each selected
prohibited frequency reference point.
1.0
1.0
0.0 to 20.0 Hz
d4-01
Frequency
Reference
Hold Function
Selection
Determines if the frequency reference
or frequency reference bias is saved
when the Run command is removed
or the power goes off.
0
0
0: Disabled
1: Enabled