Service Manual for
RCO Speed Oven
#
NAME
DESCRIPTION
SETTING DEF SETTING/RANGE
L8-05
Input Phase
Loss Protection
Selection
Selects the detection of input
current phase loss, power supply
voltage imbalance or main circuit
electrolytic capacitor deterioration.
0
0
0: Disabled
1: Enabled
L8-10
Cooling Fan
Operation
Selection
Controls the heatsink cooling fan
operation.
0
0
0: Fan On-Run Mode – Fan will
operate only when the drive is
running and for L8-11 seconds
after stop
1: Fan always on – Cooling fan
operates whenever the drive is
powered up
L8-12
Ambient
Temperature
Setting
Used to input the ambient
temperature. This value adjusts
the drive oL2 detection level.
30
30
-10 to 50 °C
L8-18 Soft CLA
Selection
Selects the software current limit
function. Typically no adjustment
is required.
1
1
0: Disabled
1: Enabled
L8-35 Installation
Method Selection Selects the installation type
0: Standard installation of open
Chassis drive
1: Side-by-Side installation with top
cover removed
2: Standard installation of NEMA
Type 1 drive
3: Finless / Fin outside installation
L8-38 Carrier Frequency
Reduction
Provides protection to the IGBTs by
reducing the carrier frequency at
low speeds.
0
1
0: Disabled
1: Enabled below 6 Hz
2: Enabled for the whole speed
range
Advanced
Program
Set Up
n1-02
Hunting
Prevention Gain
Setting
Sets the gain for the Hunting
Prevention Function. If the motor
vibrates while lightly loaded and
n1-01 = 1, increase the gain by 0.1
until vibration ceases. If the motor
stalls while n1-01 = 1, decrease the
gain by 0.1 until the stalling ceases.
1.00
1.00 0.00 to 2.50
n3-13 Overexcitation
Deceleration Gain
Applies a gain to the V/f pattern
during deceleration (L3-04 = 4).
Returns to normal values after
ramp to stop or at re-acceleration.
To increase the braking power of
overexcitation, increase the gain by
1.25 to 1.30.
1.10
1.10 1.00 to 1.40
Operator
Related
Parameters
o1-03 Digital Operator
Display Selection
Sets the units to display the
frequency reference and output
frequency.
0
0
0: 0.01 Hz
1: 0.01% (100% = E1-04)
o2-02
STOP Key
Function
Selection
Determines if the STOP key on
the digital operator will stop the
drive when operating from the
external terminals or via serial
communication.
1
1
0: Disabled
1: Enabled
o2-04 Drive Model
Selection
Sets the drive model.
0032
0032 0 to FF
o2-05
Frequency
Reference Setting
Method Selection
Selects if the ENTER key must
be pressed when inputting the
frequency reference by the
operator keypad.
0
0
0: Data/Enter key must be pressed
to enter a frequency reference
1: Data/Enter key is not required.
The frequency reference is
adjusted by the UP and DOWN
keys.