Service Manual for
RCO Speed Oven
22
Thermal Switch Connection
5. Remove the faulty switch.
6. Install the replacement Thermal Switch.
7. Referring to the tags, reconnect the switch wires.
8. Briefly reconnect the unit to its power source and
check for proper operation.
9. Remove the unit from its power source and reattach
all covers and panels.
10. Restore the unit to its power source and ensure the
unit is operating correctly. This may take several
minutes to ensure the problem has not returned.
Before performing any tests
of the unit’s operating abilities make sure a
load is placed in the oven cavity.
MAGNETRON
Before performing any service that
involves electrical connection or disconnection
and/or exposure to electrical components,
always follow the Electrical LOCKOUT/TAGOUT
Procedure. Disconnect all circuits. Failure to
comply can cause property damage, injury
or death.
The High Voltage Capacitor
retains a 2.5kV DC charge after the oven
has been disconnected from its power source.
The capacitor must be properly discharged
prior to beginning work on any components
in the high voltage area. Failure to comply
can cause property damage, injury or death.
Hot Surfaces. The Magnetron
housings may be hot.
Magnetrons
Magnetron Location
Operational Testing
The right and left Mag circuits use identical components
and wiring. Each Mag circuit has a dedicated 2.4KV
secondary supply from the Mag transformer and a high
voltage doubling circuit (capacitor and diode package)
to step up to the 4KV microwave power.
The primaries of the Mag transformers have 208V or
240V taps auto-selected by the controller PCB, based
on sensed line supply voltage to the oven through the
Tap Relay, to automatically optimize microwave power
at either the 208V or 240V line supply to the unit.
Operations of both right and left Mag circuits are
controlled through a single SSR (Solid State Relay).
The controller PCB, Primary Interlock Switch, and
Secondary Interlock Switch circuits interact to enable
or trigger the Mag SSR only when the oven door is
closed and a microwave recipe is selected.
The Monitor circuit detects failures in the Mag circuits from
the output of the Mag SSR to the Monitor Door Switch
to the Monitor Relay coil. The Monitor circuit disables
the oven by tripping the internal 30A Fast Blow Fuse
if Mag power is detected with the oven’s door open or
ajar through the output contacts of the Monitor Relay.
L1
+
MAG
T1
–
L1
30A†Fuse
208
240
NC
NO
2
NC
NO
1
230V~ COIL
Secondary
Interlock Sw.
Left
Primary
Interlock Sw.
Monitor
Relay
Tap Relay
NO = 208,††NC = 240
Bottom Right
Monitor
Sw.
Top Right
NO
NC
NO
NC
NC
NO
MAG. XFMR –
PRIMARY
MAG. XFMR –
PRIMARY
208
240
NC
NO
2
NC
NO
1
24Vdc COIL
L2
L2
L2
L2
Controller
PCB
Magnetron Control Schematic