41
Service Manual for
RCO Speed Oven
#
NAME
DESCRIPTION
SETTING DEF SETTING/RANGE
Timing
C1-01 Acceleration
Time 1
Sets the time to accelerate from 0
to maximum frequency.
3.0
10.0
0.0 to 6000.0 s
C1-02 Deceleration
Time 1
Sets the time to decelerate from
maximum frequency to 0.
6.0
10.0
C1-03 Acceleration
Time 2
Sets the time to accelerate from 0
to maximum frequency when Accel/
Decel times 2 are selected by a
digital input.
10.0
10.0
C1-04 Deceleration
Time 2
Sets the time to decelerate from
maximum frequency to 0 when
Accel/Decel times 2 are selected
by a digital input.
10.0
10.0
C1-09 Fast-Stop Time
Sets the time to decelerate from
maximum frequency to 0 for the
multi-function input fast-stop
function.
Note:
This parameter is
also used by selecting “Fast-Stop”
as a Stop Method when a fault is
detected.
10.0
10.0 0.0 to 6000.0 s
C2-01
S-curve
Characteristic at
Accel Start
S-curve is used to further soften
the starting and stopping ramp.
The longer the S-curve time, the
softer the starting and stopping
ramp.
0.20
0.20 0.0 to 10.00 s
C2-02
S-curve
Characteristic at
Accel End
0.20
0.20 0.0 to 10.00 s
C2-03
S-curve
Characteristic at
Decel Start
0.20
0.20 0.0 to 10.00 s
C2-04
S-curve
Characteristic at
Decel End
0.20
0.00 0.0 to 10.00 s
C3-01
Slip
Compensation
Gain
Sets the slip compensation
gain. Decides for what amount
the output frequency is boosted
in order to compensate the slip.
Note:
Adjustment is not normally
required.
2.2
0.0
0.0 to 2.5
C3-02
Slip compensation
Primary Delay
Time
Adjusts the slip compensation
function delay time.
2000
2000 0 to 10000 ms
C4-01
Torque
Compensation
Gain
Sets the gain for the automatic
torque (voltage) boost function and
helps to produce better starting
torque.
1.00
1.00 0.00 to 2.50
C6-01 Normal/Heavy
Duty Selection
Selects the load rating for the
drive. This setting affects the
Rated output current and overload
tolerance of the drive.
0
1
0: Heavy Duty (HD) for constant
torque applications
1: Normal Duty (ND) for variable
torque applications
C6-02 Carrier Frequency
Selection
Selects the carrier frequency
0004
0004
1: 2.0 kHz
2: 5.0 kHz
3: 8.0 kHz
4: 10.0 kHz
5: 12.5 kHz
6: 15.0 kHz
7: Swing PWM
8 to E: No setting possible
F: User defined (determined by
C6-03 through C6-05)