Service Manual for Flexible Batch Broiler, CE Version
28
6/19/2014
SM-BR-BR-0007
UPPER IR BURNER AIR sUPPLY
The adjustments for the Upper IR Burner air
supply are accessible by removing the Upper Lift
Off Panel. There are two air adjustment screws
located on each side of the blower hose.
NOTE:
The air adjustment is factory set and
must not be changed unless authorized to do so
by Duke Manufacturing.
1. Remove the Upper Lift Off Panel.
2. If found loose, it may be necessary to re-adjust
and re-tighten the locking nuts which secure
the air adjustment screws.
Air Adjustment Screws
IR Burner Air Adjustment screws
LOWER BURNER AIR sUPPLY
The adjustment for the lower burner air supply is
factory set and must not be changed. A properly
adjusted natural gas burner has a blue flame
around the burner bend with no yellow tips on
the flame. A propane gas burner may have a
small amount of yellow tips on the flames. The
Air Shutter opening on factory J Burners is preset
and welded. If replacing the J Burner, verify this
opening before installing it.