Replacing Conveyor Links
WARNING
DIsCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDUREs.
1. Turn off and unplug the broiler.
2. Remove the front operator parts and panels.
Refer to the COVERS and PANELS section
of the manual.
3. Spread the damaged link with Link Tool at both
ends.
4. Remove the damaged link.
5. Install the new link.
6. Use pliers to close both ends of the link.
7. Check for proper operation. It may be
necessary to add or remove shims behind or
under the bushing blocks to ensure proper
tension.
NOTE:
Never remove a link without replacing
a link.
Spread links
Conveyor Links