Service Manual for Flexible Batch Broiler, CE Version
20
6/19/2014
SM-BR-BR-0007
Ignition Modules
The Ignition Modules are accessible by removing
the Lower Control Side Service Panel. The Ignition
Modules are at the bottom of the compartment
behind the Relays.
WARNING
DIsCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDUREs.
1. Remove the Lower Control Side Service Panel.
Refer to the COVERS and PANELS section
of the manual.
2. Tag and disconnect the wires to the Ignition
Module to be removed.
3. Disconnect the Flame Sensor wire/s.
4. Remove the two screws attaching Ignition
Module to frame and remove the module.
5. Reverse this procedure to replace an Ignition
Module.
Lower
Ignition
Module
Upper
Ignition
Modules
Screws
Flame Sensor
Wires
Ignition Modules
Combo Gas Valves
WARNING
DIsCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDUREs.
WARNING
sHUT OFF THE GAs sUPPLY
BEFORE sERVICING THE UNIT.
WARNING
CHECK ALL GAs JOINTs DIsTURBED
DURING sERVICING FOR LEAKs.
CHECK UsING A sOAP AND WATER
sOLUTION (BUBBLEs). DO NOT UsE
AN OPEN FLAME.
WARNING
ALL JOINTs PRIOR TO THE COMBO
GAs VALVE MUsT BE CHECKED
BEFORE LIGHTING THE UNIT.
WARNING
ALL JOINTs BEYOND THE COMBO
GAs VALVE MUsT BE CHECKED
AFTER UNIT Is LIT.