Service Manual for Flexible Batch Broiler, CE Version
18
6/19/2014
SM-BR-BR-0007
5. Pinch tabs on the wire grommet to remove it.
6. Feed the wire through the hole to fully remove
the Flame Sensor Assembly.
7. Reverse procedure to install a new Lower
Flame Sensor Assembly.
Lower Igniter Assembly
The Lower Igniter Assembly is accessible by
removing the Upper Lift Off Panel.
WARNING
DIsCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDUREs.
1. Remove the Upper Lift Off Panel. Refer to the
COVERS and PANELS section of the manual.
2. Disconnect Lower Igniter cable and ground
wire from the Igniter.
3. Remove the nut securing the Igniter.
4. Reverse procedure to install a new Lower
Igniter Assembly, ensuring the replacement
Igniter has the proper 3.175 mm spark gap.
For proper ignition, the spark should be
approximately 19.05 mm above the lower
burner.
Upper Infrared Burner Assembly
There are two Infrared Burners located on the
top of the broiler. These Infrared Burners can be
accessed by removing the Top Service Panel and
Impedance Pan.
WARNING
DIsCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDUREs.
WARNING
sHUT OFF THE GAs sUPPLY
BEFORE sERVICING THE UNIT.
WARNING
CHECK ALL GAs JOINTs DIsTURBED
DURING sERVICING FOR LEAKs.
CHECK UsING A sOAP AND WATER
sOLUTION (BUBBLEs). DO NOT UsE
AN OPEN FLAME.
Caution: If the broiler has been operating,
broiler panels and components
may be hot. Use proper
protection.
1. Remove Impedance Pan. Refer to the
COVERS and PANELS section of the manual.
2. Remove Lower Control Side Service Panel.
Refer to the COVERS and PANELS section
of the manual.
3. Disconnect gas line at input to top Infrared
Burner Assembly to be removed.
4. Remove nuts which run along the length of
the burner.
5. Remove both Igniter Guards.
6. Remove Blower Hose.
7. Remove Air Box Cover.
8. Remove the four screws that secure the Burner
Venturi to the Air Box.
9. Use a putty knife to gently pry the Burner
Venturi from the Air Box.
10. Lift Infrared Burner Assembly out of top of
broiler, by sliding the burner forward, up and
out of the broiler.
11. Reverse procedure to install a new Infrared
Burner Assembly.