Service Manual for Flexible Batch Broiler, CE Version
24
6/19/2014
SM-BR-BR-0007
Main Power switch
The Main Power Switch is located on the front of
the broiler below the Control Board.
WARNING
DIsCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDUREs.
1. Remove Lower Control Side Service Panel.
Refer to the COVERS and PANELS section
of the manual.
2. Disconnect switch wires.
3. Pinch the spring tabs on the top and bottom of
the switch and slide out through front of panel.
4. Reverse procedure to install a new Main Power
Switch.
Main Power switch
Blower Motor
The Blower Motor is located on the Control Board
side of the broiler and is accessed by removal of
the Upper Lift Off and Lower Control Side Service
Panels.
WARNING
DIsCONNECT THE ELECTRICAL
POWER TO THE BROILER AND
FOLLOW LOCKOUT / TAGOUT
PROCEDUREs.
1. Remove the Upper Lift Off Panel. Refer to the
COVERS and PANELS section of the manual.
2. Remove the Lower Control Side Service Panel.
Refer to the COVERS and PANELS section
of the manual.
3. Disconnect wires from the Blower Motor.
4. Loosen Blower Hose clamp and disconnect
the hose from top of Blower Motor.
5. Remove three screws attaching Blower Motor
to frame.
6. Reverse procedure to install a new Blower
Motor. Replace gasket when installing new
Blower Motor.
Blower Motor
Assembly
Screws
Hose
Clamp
Blower Motor