Service Manual for Flexible Batch Broiler, CE Version
26
6/19/2014
SM-BR-BR-0007
5. Turn gas supply on.
NOTE:
The pressure regulator is an integral part
of the Combo Gas Valve.
6. Locate the Outgoing Pressure Adjustment
which lies just behind the Outgoing Pressure
Tap. The adjustment will require a standard
Allen wrench.
7. For the correct pressure measurement, refer
to the Specification / Data Label on the Broiler.
8. Turn gas supply off.
9. Disconnect meter.
10. Re-tighten the screw into the Outgoing
Pressure Tap.
11. Turn gas supply back on.
12. Check for any gas leaks.
13. Check broiler operation.
DRIVE CHAIN DEFLECTION ADJUsTMENT
The Drive Chain connects the drive motor to the
Conveyor.
1. Check that the deflection in the Drive Chain
does not exceed 4.763 mm maximum. If the
chain requires adjustment, proceed to step 2.
2. Remove Discharge Access Panel. Refer to the
COVERS and PANELS section of the manual.
3. Remove Conveyor Drive Motor Cover.
4. Loosen the four screws securing the motor
mount to the frame.
5. Move the motor mount up or down as necessary
to provide 4.763 mm deflection at center of
chain.
6. Secure the motor mount in place by tightening
the four motor mount screws.
7. Install Conveyor Drive Motor Cover.
8. Install Discharge Access Panel.
ADJUsTMENTs
COMBO GAs VALVE
The two Combo Gas Valves are located next
to each other and are accessible by removing
the Lower Control Side Service Panel. One gas
valve is for the Lower J Burner and the other gas
valve is for the Upper Infrared Burners. The gas
pressure has been preset at the factory for the type
of gas specified on the rating plate; however, it is
sometimes necessary to adjust the gas pressure
after the unit has been installed. Always check
the incoming gas pressure at the tap provided on
the gas valve before making any valve pressure
adjustments. Valve adjustments must be made
when both valves are fully open with all burners
operating.
Burner
Gas Lines
Input
Gas Lines
Upper
Combo Gas Valve
Lower
Combo Gas Valve
Incoming
Pressure Tap
Outgoing
Pressure Tap
Outgoing
Pressure
Adjustment
Combo Gas Valve
1. Turn the incoming gas supply to the broiler
off.
2. Remove the Upper Lift Off Panel. Refer to the
COVERS and PANELS section of the manual.
NOTE:
Do not disconnect any wiring.
3. Loosen the outgoing pressure tap screw. Screw
is not designed to come out.
4. Attach a gas pressure meter, slack tube, or
manometer to the tap.