contribute to errors or false readings. Inaccurate or false readings of the outlet sensor will adversely
affect control of the dryer by the Dryer Master.
Locate the Sensor so it can be
safely
accessed for cleaning and taking grain samples.
Installation Procedure
1.
Remove the Outlet Sensor from the 6” square chute before welding
or bolting the chute in
place.
2.
Make the necessary changes to the discharge system of the dryer so that there is room for
the chute; rotary feeder or slide restrictor.
3.
Install the shut off slide gate above the sensor to shut off the flow to the sensor to allow
cleaning out and or servicing the sensor.
4.
Install bars across the opening to the sensor in the direction of grain flow. This will prevent
large objects from entering the sensor.
5.
Mount the chute in a vertical position.
6.
Bolt the fin sensor back into the chute.
Do not cut holes in the Outlet Sensor. Use only the existing wire entry
location. Entry at any other location voids the warranty.
Ensure the sensor chute empties completely when shutting down. Make electrical connections such
that the chute power is tied to the elevator control circuit. The elevator is typically the last item shut
down in the shutdown sequence.
Main Product Flow
Sample access
Moisture Sensor
Rotary metering
device
Grain Sample Return
Shutoff slide
9 5/8",
24.5cm
6 5/8",
16.8cm
Figure 10 - By-Pass with rotary metering