Page | 35
Dryer Master DM510
Installation Manual
DM510 Control Panel Installation
Control Panel Location
The DM510 Control Panel must be located in a reasonably well-controlled and secure environment.
Use the following guidelines to locate the best position for the DM510 Control Panel where:
•
It is protected from the weather. (And is as free from dust as possible if the optional printer
is used).
•
The ambient temperature during operation will be between 40° and 105°F (5° and 40°C).
•
Someone can hear the alarm buzzer.
•
The bottom of the display screen (LCD) is slightly above average eye level.
•
Locate DM510 in a room where the dryer operators will spend most of their time or will be
processing moisture samples.
•
If the DM510 is mounted against an uninsulated outside wall, provide ½" (12.7mm) insulating
panel (wood).
Control Panel Installation
Refer to Figure 21
–
DM510 Control Panel Dimensions while doing the following:
1.
Drill all holes and insert ¼" (6mm) bolts with washers into bottom holes. Leave space
between washer and wall
2.
Slide cut-out slots in bottom mounting tab on Controller under washers
3.
Align top holes. Insert screws and washers in top mounting tab, level the box and tighten all
screws