Page | 24
Dryer Master DM510
Installation Manual
Sensor Installation
1.
Refer to Figure 7 - Alternate location for inlet sensor on column dryer and Figure 8 - Round
dryer installation location.
2.
Cut an opening through the side of the garner bin the same size or slightly larger than the
opening in the mounting plate (Figure 6 - Sensor and mounting plate dimensions) making
sure that the completed installation will be level.
3.
Weld or bolt the mounting frame to the outside wall of the garner bin to cover the hole such
that the sensor can be mounted through the plate without binding.
4.
Bolt the Sensor to the mounting frame. Make sure that the sensor is mounted such that the
wire entry will be down.
If you are unsure of where to locate the sensor contact the Dryer Master Support Center.
It is preferable to do it right the first time.
Note:
Locate the sensor where it is in constant contact with the compacted grain. If the sensor is not
in constant contact with compacted grain and becomes empty or becomes partially empty,
the DM510 will trigger an alarm condition. The DM510 may (as a result of the alarm)
relinquish automatic control.