Page | 17
Dryer Master DM510
Installation Manual
Inlet Moisture Sensor
The inlet sensor is to be mounted in a location that will provide a representative sample of grain
entering the dryer. It should be located where there will be a regular flow of product past the sensor
(at no faster than 1 inch per second
–
slower is fine), and in an area where debris is unlikely to
accumulate.
Communication with DMSI Engineering personnel could result in revisions to the installation method
if readings are not representative. DMSI Project Engineering can advise you of modifications to the
required installation.
Installed the inlet moisture sensor as specified
Connected the inlet moisture sensor as specified
Installed in a Non Hazardous location
Outlet Moisture Sensor
The sensor is to be mounted in a chute that will provide product flow at a rate of approximately 0.5"
to 1" (1.25cm to 2.5cm) per second. The Dryer Master inline and bypass chutes with rotary feed are
designed to meet these requirements. If an alternate configuration is used specifications for the
chute dimensions and product conveyance methods are provided in separate mechanical drawings.
Communication with DMSI Engineering personnel could result in revisions to the installation method
if the flow rate is not within specification. DMSI Project Engineering can advise you of modifications
to the required installation.
Installed the sensor chute as specified
Installed the outlet moisture sensor as specified
Connected the outlet moisture sensor as specified
Installed in a Non Hazardous location
Sample Station (calibration push button)
The Sample Station consists of a Normally Open Push Button Contact and a 24 VDC LED Lamp. The
Sample Station should be placed in close proximity to the outlet Moisture Sensor. The purpose of
the station is to signal the DM510 control panel that a moisture sample has been taken and to tell
the operator for how long to take a sample.
Installed the Sample Station (Push Button and 24VDC Lamp) as specified
Connected the Sample Station (Push Button and 24VDC Lamp) as specified
Air Plenum Temperature probe (Temperature Option A)
The DM510 control panel's hot air plenum temperature sensor is to be installed within 6-12" of the
dryer's air plenum temperature sensor.