34
F_25
: Return to Factory Pre-Settings
= 010 : Constants initialization to 50Hz system Traverse mode
= 011 : Constants initialization to 50Hz system Hoist mode
= 020 : Constants initialization to 60Hz system Traverse mode
= 021 : Constants initialization to 60Hz system Hoist mode
1.
When F_25 is set to 010 or 011, all parameters are restored to 50 Hz factory settings. The
settings of F_05 =1, F_06 = 50, F_26=25, and F_27=50. F_25 is restored back to 000 after
the reset process is complete. (50Hz operation)
2.
When F_25 is set to 020 or 021, all parameters are restored to 60 Hz factory settings. The
settings of F_05 =3 and F_06 = 60, F_26=30, and F_27=60. F_25 is restored back to 000
after the reset process is complete. (60Hz operation)
F_26
: SP2(00.0 - 01.0~200Hz) , Multi-speed2
(Reference to F_19 and F_20)
F_27
: SP3(00.0 - 01.0~200Hz) , Multi-speed3
(Reference to F_19 and F_20)
F_28
: Voltage Stall level range: = 000~001
Setting 000 disables voltage stall function during inverter regeneration mode.
Setting 001 enables voltage stall function during inverter regeneration mode.
Warning! Do not operate Hoist with F_28 ON = 001
F_29
: CPU program version. Displays loaded program version.
F_30
: Fault log
1.
Last three faults : indicate the sequence of the occurrence of malfunctions by the location of
decimal point.
x.xx
indicates a recently happened malfunction.
xx.x
indicates the previous malfunction
that happened.
xxx.
Indicates the earliest malfunction in the record.
2.
After entering the F_30 function, the
x.xx
trip record will be displayed first. After that, press UP
arrow button and you can read activity in a chronological order.
xx.x
••
xx x.
••
x.xx
consecutively.
3.
After entering F_30 function, if the RESET button is pressed, the trip record will be cleared.
Indication display
-.—
,
—.-
, and
—.
4.
When the content of trip indicates O
.
CC, it will indicate the trip code is OC.C and so on.