32
4.
F_19, F_20=004:
Reset input when inverter faults.
Note: Inverter must be in STOP mode to reset.
(All run signals OFF)
5.
F_19, F_20=005:
Creep input. See function F_03 page 25
6.
F_19, F_20=006:
Top Limit. See function F_03 page 25
F_21
: Multifunctional output terminal control range: 001~005
1.
F_21=001:
Run mode signal operating
2.
F_22=002:
At frequency speed signal
3.
F_21=003:
Fault signal
Terminal 1 and 2 of TM2 / TB1 are activated at the following fault conditions:
CPF, OL1, OL2, OCS, OCA, OCC, Ocd, Ocb, OVC, LVC, OHC
4.
F_21=004:
At current detect level set at F_22.
5.
F_21=005:
At frequency detect level set at F_23