33
F_22
: Output current detect level range: 000~150%
Trigger level of multifunction output when F_21=004. Sets level where output switches to active state.
Hysteresis is 10% of set point.
F_23
: Output frequency detect level range: 01.0~200
Trigger level of multifunction output when F_21=005. Sets level where output switches to active state.
Hysteresis is 1.0% of set point.
F_24
: Number of Auto-restart times range: 000~005
1. When F_24 = 0, the inverter will not try to restart.
2. When F_24 does not = 0, the inverter will resume operation via SPEED SEARCH at approximately
0.5 second after a function trip. After that, the inverter will accelerate or decelerate to the current
frequency setting.
3. When the inverter is set to deceleration or DC braking, the transient restart procedure is not per-
formed.
4. If either of following situations should develop, the auto restart times will be reset:
(1)
No additional malfunction (in operation or stop) occurs within 10 minutes.
(2)
Press RESET button.
WARNING! Do not use when operating a hoist or any other manually operated equipment.