F_12
Carrier frequency
F_12
Carrier frequency
F_12
Carrier frequency
001
4 kHz
005
8 kHz
009
15 kHz
002
5 kHz
006
10 kHz
010
16 kHz
003
6 kHz
007
12 kHz
004
7.2 kHz
008
14.4 kHz
28
F_11
: Speed Control range: 000~005
= 000 :
Keypad
= 001 :
Analog Speed Pot Terminal (TM2 / TB1) ( 0 ~ 10V / 0-20mA )
= 002 :
Analog (TM2 / TB1) (4-20mA)
= 003 :
1~3 preset speeds
= 004 :
2 step infinitely variable
= 005 :
3 step infinitely variable
NOTE 1:
When Sp1 frequency is
switched on, the frequency is setup by Sp1
speed, the up/down buttons on the keypad are
disabled.
Original setting will be restored after the Sp1
connection is removed.
F_12
:
Carrier Frequency range: 001 ~ 010
NOTE: If F_12=7~10,the inverter must be operated at 75% of full load or less.
Although an IGBT TYPE inverter can provide a low audible noise level during its operation, it is possible
that the switching of the high carrier frequency may interfere with external electronic components (or
other controllers) or even cause vibration in the motor. Adjusting the carrier frequency can usually correct
this problem.
F_13
: Torque compensation gain range: 000 ~ 10.0 %
To enhance Inverter output torque response according to the B, C voltage points on the V/F pattern
(refer to F_05 description)
F_13 provides a 0-10% increase to voltage points B and C.
F_06
0mA
0V
4mA
20mA
10V
F_11=1
F_11=2
Содержание Crane Commander CCES102
Страница 16: ......
Страница 17: ......
Страница 20: ...18 Dimensions and installation of class B filter Models CCES215 CCES222 CCES407 CCES415 CCES422...