25
F_03
: Creep / Top Speed divisor ratio.
Ratio of operating speed when creep input or top speed limit is enabled.
Range: 001~030
Note 1: F_03 is only effective when F_19 or F_20 is programmed for creep input or top limit input.
Creep and top limit are effective in any mode of speed control set at F_11.
F_04
: Motor rotation direction setting.
Range:
000: Forward
001: Reverse
Although there is no Forward / Reverse push button on the digital control panel, it is possible to adjust
forward / reverse function by changing the F_04 setting. This function is only available when F_10=0.
(keypad operation)
Note:
Keypad operation permits only momentary operation (inverter stops when RUN button is
released)