26
F_05
: V/F pattern setting = 1~4
Setting F_05 range: = 1~4 to select one of the 4 preset V/F patterns. (Refer to the following tables)
100
B
C
V (%)
1 2
.
5 50
120
Hz
100
B
C
V (%)
1 2
.
5
50 120
Hz
100
B
C
V (%)
1
3
.
0 60
120
Hz
100
B
C
V (%)
1
3
.
0
60 120
Hz
Specification
50 Hz System
Application
General Application
High starting torque
F_5
001
002
V/F Pattern
Specification
60 Hz System
Application
General Application
High starting torque
F_5
003
004
V/F pattern
F_5
B
C
1/3
10%
8%
2/4
15%
10.5%
Содержание Crane Commander CCES102
Страница 16: ......
Страница 17: ......