During examination and maintenance
CAUTION!
•
Inverter environment should be within -10°C and +40°C, humidity should be under 95%
RH non-condensing.
CAUTION!
•
If operating without enclosure (chassis mount), the environment temperature should be
within -10°C and +50°C and the humidity should be under 95% RH non-condensing.
Also, the surrounding environment should be free from moisture or metal dust.
Typically the inverter requires no special maintenance. However, Drivecon suggests inspec-
tion of the inverter with special attention to loose wiring connections. Excessive accumulation
of dust or dirt will also shorten the expected life of the inverter. Periodic cleaning of the in-
verter with dry compressed air may be required.
WARNING!
•
Insure power supply is switched OFF and the LED charge indicator has extinguished
prior to inspection or maintenance of inverter. Lock out all equipment under repair or
inspection.