January 2001
5K - 9
Functions - Power Supply and Control
Service Manual Cafitesse 500
●
The service board (6) is coated against
humidity.
Therefore, the plug (7) at the service board
must not be unplugged. (Fig. 4)
●
Open the control board box (8) and remove
the corresponding plug (9) from the
interconnector board (10). (Fig. 5)
When remounting, make sure that the
interconnector board (10) of the control
board box is positioned correctly.
(Fig. 5)
●
Dismounting the board:
- Remove the 4 screws (11) of the board
support. (Fig. 4)
- Remove the board support (12). (Fig. 4)
- Remove the board (6). (Fig. 4)