January 2001
5A - 24
Functions - Water System
Service Manual Cafitesse 500
A.3.3 Function: Overflow
●
If a malfunction occurs (e.g. the inlet valve
does not close in time) water is discharged
into the overflow trap between boiler and
boiler insulation.
●
The water is led from the drain adaptor to
the drip tray.
●
The opening of the overflow is covered with
a rubber trap to prevent steam losses.
A.3.4 Function: Water Inlet
●
The water inlet is located on the bottom of
the container. It is connected to the inlet
valve by a hose connection.
●
The essential parts of the inlet valve are
(fig. 1):
-
the diaphragm with cleaning wire (1)
-
the tappet (2)
-
the coil
-
the valve housing (3) with sieve, flow
rate controller and outlet spout.
●
When the valve is closed, the tappet closes
the bore in the middle of the diaphragm.
Fig. 1
2
1
3
Содержание CAFITESSE 014
Страница 4: ......
Страница 59: ...January 2001 3 13 Trouble Shooting Error Codes and Fault Diagnosis Service Manual Cafitesse 500 3 3 Notes ...
Страница 92: ...January 2001 4 33 Programming Service Manual Cafitesse 500 4 3 Reading further Data Not included ...
Страница 104: ...January 2001 5 12 Functions Service Manual Cafitesse 500 Fig 8 ...
Страница 214: ...January 2001 5K 17 Functions Power Supply and Control Service Manual Cafitesse 500 K 4 Electrical Diagrams ...
Страница 225: ...January 2001 7 2 Service Procedures Service Manual Cafitesse 500 7 Service Procedures 7 1 Dispenser SIS Code List ...
Страница 226: ...January 2001 7 3 Service Procedures Service Manual Cafitesse 500 7 2 Warranty and Parts Return ...
Страница 229: ...January 2001 8 1 Service Information Service Manual Cafitesse 500 8 Service Information ...
Страница 230: ...January 2001 9 1 Modification Instructions Service Manual Cafitesse 500 9 Modification Instructions ...