5F - 14
Functions - Cooling System
Service Manual Cafitesse
500
Supervision Peltier current
●
The value of the Peltier current is detected
by the voltage difference. It is measured by
means of a test resistor (0.1 Ohm, on the
control board).
●
The cooling is switched off in order to
protect the Peltier element from damage
due to a short-circuit when:
-
for 1 sec. the electric current is higher
than 6 A
(error indication 6)
or
-
when for 1 sec. the electric current is
less than approx. 1.7A (error indica-
tion 7).
This error can be caused by a lack of
heat absorption from the heat sink (it is
either very dirty or the fan does not
work). If the temperature of the heat sink
rises the electric current through the
Peltier element decreases.
●
Normally (in a stable, cooled condition) the
Peltier current is in the range of 3.1–5.2 A.
In the first minute after a current
interruption it can be up to 15 % higher.
Содержание CAFITESSE 014
Страница 4: ......
Страница 59: ...January 2001 3 13 Trouble Shooting Error Codes and Fault Diagnosis Service Manual Cafitesse 500 3 3 Notes ...
Страница 92: ...January 2001 4 33 Programming Service Manual Cafitesse 500 4 3 Reading further Data Not included ...
Страница 104: ...January 2001 5 12 Functions Service Manual Cafitesse 500 Fig 8 ...
Страница 214: ...January 2001 5K 17 Functions Power Supply and Control Service Manual Cafitesse 500 K 4 Electrical Diagrams ...
Страница 225: ...January 2001 7 2 Service Procedures Service Manual Cafitesse 500 7 Service Procedures 7 1 Dispenser SIS Code List ...
Страница 226: ...January 2001 7 3 Service Procedures Service Manual Cafitesse 500 7 2 Warranty and Parts Return ...
Страница 229: ...January 2001 8 1 Service Information Service Manual Cafitesse 500 8 Service Information ...
Страница 230: ...January 2001 9 1 Modification Instructions Service Manual Cafitesse 500 9 Modification Instructions ...