January 2001
2 - 6
Installation / Putting into Operation
Service Manual Cafitesse 500
2.2.3 Electrical Supply
Fig. 1
1 - Power cord
2 - Water connection for the delivery of
café cool, iced cappuccino (optional)
3 - Water connection
1
2
3
●
The dispenser must be connected to a correctly fused electric circuit. Connection to a supply with
a ground fault current safety switch is recommended. The connection must be made using a plug
and socket grounded and sized according to local regulations.
Voltage
Tank Wattage
Total Wattage
Actual Amps
Breaker Size
120
1600
1800
15
20
208/240
2200/2900
2400/3100
11.5/12.9
20/20
208/240
2700/3600
2900/3800
13.9/15.8
20/20
208/240
4200/5600
4400/5800
21.2/24.2
30/40
208/240
6600/8700
6800/8900
32.7/37.5
50/50
Содержание CAFITESSE 014
Страница 4: ......
Страница 59: ...January 2001 3 13 Trouble Shooting Error Codes and Fault Diagnosis Service Manual Cafitesse 500 3 3 Notes ...
Страница 92: ...January 2001 4 33 Programming Service Manual Cafitesse 500 4 3 Reading further Data Not included ...
Страница 104: ...January 2001 5 12 Functions Service Manual Cafitesse 500 Fig 8 ...
Страница 214: ...January 2001 5K 17 Functions Power Supply and Control Service Manual Cafitesse 500 K 4 Electrical Diagrams ...
Страница 225: ...January 2001 7 2 Service Procedures Service Manual Cafitesse 500 7 Service Procedures 7 1 Dispenser SIS Code List ...
Страница 226: ...January 2001 7 3 Service Procedures Service Manual Cafitesse 500 7 2 Warranty and Parts Return ...
Страница 229: ...January 2001 8 1 Service Information Service Manual Cafitesse 500 8 Service Information ...
Страница 230: ...January 2001 9 1 Modification Instructions Service Manual Cafitesse 500 9 Modification Instructions ...