January 2001
3 - 9
Trouble Shooting, Error Codes and Fault Diagnosis
Service Manual Cafitesse 500
ERR16
24 V error
24 V-supply or safety
circuit is interrupted.
The LEDs for "EMPTY"
and "ON/OFF" are
flashing. The dispenser is
switched off. The cooling
system remains on.
ERR17
Low level
(not enough water in the
boiler)
Inlet valve has not been
detected within
several sec. (approx. 10)
after the outlet valve is
opened.
The LEDs for "EMPTY"
and "ON/OFF" are
flashing. The dispenser is
switched off. The cooling
system remains on.
ERR18
Left mixer motor current
I
mixer
is less than 0.1 A for
100 msec
The LEDs for "EMPTY" and
"ON/OFF" are flashing.
The dispenser remains on
The delivery of all products
for which the left mixer motor
is used is blocked.
All products for which the
left mixer motor is not used
can be delivered.
Cooling remains on.
During the 'FLUSH'
procedure the defective
mixer remains off.
Display
Error
Cause
Remedy
1. The water in the boiler
has boiled. Boil over
protection was triggered
2. Float is stuck in upper
position. Dry running
protection was triggered
3. Fuses, wires P04 in the 24 V
circuit defective
4. Switching mode console
defective
1.Optical sensor, float in the
boiler or wires P02/11-13
(BU24) defective
2. Solenoid valve (inlet or
outlet) or
wires P02/1-6 (BU 24)or
P13/1,2 (BU 23)
defective.
1. Plug defective (P06).
2. Wires P06 to the motor
defective
3. Motor defective
1.Check temperature sensor,
reset boil over protection (see
pg. 5.A-23)
2. Check the float, reset the dry
running protection (see pg.
5.A-23)
3. Check the wires P04 and
replace control board if
necessary (see pg. 5K-4)
4. Check the switching mode
console, replace it if
necessary (see pg. 5.K-3)
1. Check the wires, replace the
optical sensor or float (see
pg. 5.A-13/14).
2. Check the wires or replace
the valves (see pg. 5.A-16
pp.).
1. Replace the plug. (6-poles
connector and BU23)
2. Check the wires.
(6-poles connector from
whipper motor)
3. Check or replace motor. (see
pg. 5.C-8)
Содержание CAFITESSE 014
Страница 4: ......
Страница 59: ...January 2001 3 13 Trouble Shooting Error Codes and Fault Diagnosis Service Manual Cafitesse 500 3 3 Notes ...
Страница 92: ...January 2001 4 33 Programming Service Manual Cafitesse 500 4 3 Reading further Data Not included ...
Страница 104: ...January 2001 5 12 Functions Service Manual Cafitesse 500 Fig 8 ...
Страница 214: ...January 2001 5K 17 Functions Power Supply and Control Service Manual Cafitesse 500 K 4 Electrical Diagrams ...
Страница 225: ...January 2001 7 2 Service Procedures Service Manual Cafitesse 500 7 Service Procedures 7 1 Dispenser SIS Code List ...
Страница 226: ...January 2001 7 3 Service Procedures Service Manual Cafitesse 500 7 2 Warranty and Parts Return ...
Страница 229: ...January 2001 8 1 Service Information Service Manual Cafitesse 500 8 Service Information ...
Страница 230: ...January 2001 9 1 Modification Instructions Service Manual Cafitesse 500 9 Modification Instructions ...