A.2.6 Disassembly of the Optical Sensor
Fig. 1
Preparation:
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the housing cover (see pg. 5.G-2).
●
Remove the air chute (see pg. 5.G-5).
Disassembly:
●
Take the float support out of the optical
sensor (pull it up and turn it sideways).
●
Unplug the plug from the optical sensor.
(Fig. 1)
●
Remove the defective optical sensor.
●
Insert the new optical sensor into the plate
by means of the snap hooks. (Fig. 1)
●
Connect the plug to the optical sensor.
Make sure the polarity is correct!
●
Insert the float support into the optical
sensor.
●
Assemble the dispenser.
Содержание CAFITESSE 014
Страница 4: ......
Страница 59: ...January 2001 3 13 Trouble Shooting Error Codes and Fault Diagnosis Service Manual Cafitesse 500 3 3 Notes ...
Страница 92: ...January 2001 4 33 Programming Service Manual Cafitesse 500 4 3 Reading further Data Not included ...
Страница 104: ...January 2001 5 12 Functions Service Manual Cafitesse 500 Fig 8 ...
Страница 214: ...January 2001 5K 17 Functions Power Supply and Control Service Manual Cafitesse 500 K 4 Electrical Diagrams ...
Страница 225: ...January 2001 7 2 Service Procedures Service Manual Cafitesse 500 7 Service Procedures 7 1 Dispenser SIS Code List ...
Страница 226: ...January 2001 7 3 Service Procedures Service Manual Cafitesse 500 7 2 Warranty and Parts Return ...
Страница 229: ...January 2001 8 1 Service Information Service Manual Cafitesse 500 8 Service Information ...
Страница 230: ...January 2001 9 1 Modification Instructions Service Manual Cafitesse 500 9 Modification Instructions ...