Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Safety
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
17 / 156
- Certification number
- Discharge energy
- Maximum output current
- Maximum output voltage
- Input voltage
- Input frequency
- Power consumption
- Maximum surface temperature
- Maximum control air pressure
- Maximum material pressure
- CE labeling
- Manufacturer’s data
- QR Code
The atomizer fulfills the following requirements according to the ATEX
guideline:
Device group
Device category
Temperature
class
Discharge energy
II
2G
T4
<350mJ
II
3G
T4
<350mJ
The atomizer may be operated in the zone 1 and 2. For this purpose,
the operating parameters given on the type plate should be noted.
The atomizer is not suitable for operation in zone 0.
The use of atomizers as device of the category “2G” is permitted
exclusively in combination with the following Dürr Systems products:
- High voltage generator
- Controller
- Wiring board
- R/O converter
- Flange package
- Bell disk
- High voltage line with plug
If the atomizer is operated with components from other manufacturers,
the only use allowed is as a device of the “3G” category.
Special conditions for operation
The atomizer is to be operated in the “I-constant” operating mode in
the entire setting range as equipment of type A-NL with a discharging
power <350mJ.
Pos: 10 /INP/ Bell2/02_06 Restrisiken @ 59\mod_1544782120876_20.docx @ 645133 @ 23335 @ 1