Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Introduction
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
11 / 156
If the atomizer is integrated in a total system, all technique-specific
and safety standards as well as the valid specifications must be
fulfilled.
Follow the following European standard in respect of coating materials
and application process for the atomizer with external charging:
- EN 50348 Stationary electrostatic application equipment for non-
flammable liquid coating material - Safety requirements
The atomizer is classified for all process variants as atomizer of the
type A-NL according to this standard.
If you have questions regarding the application range, our Service
Department is at your disposal.
Restrictions for Atomizers with Recirculation:
In atomizers with recirculation, work only with slow-drying 2K paints.
Do not use isocyanate based and epoxy resin based hardeners.
According to the ATEX Guideline, the atomizer type tested as device
of the category 2G and for is approved for use in explosive areas of
Ex zones 1 and 2. This permission is valid according to the type test
certificate and the details on the type plate exclusively in combination
with the assigned and in the declaration of conformity in accordance
with the ATEX Guideline listed products from Dürr Systems:
- High voltage generator
- Controller
- Wiring board
If the atomizer is operated with products from another manufacturer,
only a device of the category 3G and in Ex-zone 2 can be used.
Independently of the painting parameters, the deployment of the
atomizer is only allowed according to the technical data, for example,
within the specified temperature range and the specified relative
humidity.
A deployment under any conditions other than those mentioned in the
operation manual is not allowed.
Technical data and limits of use to be observed are included in these
operation manual and in the drawings, schemata and parts lists
associate with this product.
Failure to use the atomizer as intended is potentially very dangerous.
The specifications and notes in these instructions must be absolutely
followed for its intended use.
The atomizer and its attachments are free of LABS.