Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Cleaning and maintenance
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
81 / 156
C A U T I O N
Risk due to rotating bell disk
There is a risk of deep cuts.
Make sure that the bell disk is standing still before carrying out any
work on the atomizer. An unintentional turning on of the turbine must
be prevented.
W A R N I N G
Danger of damage to hearing
Loud noises occur when disconnecting pneumatic lines under
pressure. The hearing may be damaged.
Never disconnect lines under pressure. Wear ear protection.
W A R N I N G
Danger due to electrostatic charge
Danger to personnel due to electrostatic discharge when touching the
cable cover.
Use a grounding rod to discharge the complete cable cover in the
paint booth before all maintenance and repair work.
7.1.1
Cleaning
Always wear suitable protective clothing, shoes, gloves, and safety
glasses.
Consider the quality of the inhaled air. Work on the atomizer only if
you are sure that the inhaled air meets health standards.
The spraying system must be in the “Cleaning" mode before you enter
the spray booth. Make sure that nobody can switch on the system
again, as long as someone is in the spray booth.
Bear in mind the manufacturer’s specification for paint, detergent, and
rinsing agent.The associated approved and permitted detergents and
cleaning agents must also be non-flammable.
A T T E N T I O N
Risk of damage to property and production disruption
Moisture may enter and damage the atomizer.
Only use damp cloths for cleaning, no wet cloth.