Operating Manual
© Dürr Systems AG
EcoBell2 SL EC - Rotating Atomizer with External Charging
Cleaning and maintenance
Document No.: MRA00001EN
Version:: 07
•
As of:: 01/2020
83 / 156
W A R N I N G
Danger from harmful or irritant substances
If you come in contact with hazardous liquids or vapors, death or
serious injury can result.
Obtain information about the specific risks of the materials used. Note
the safety recommendations of the material manufacturer.
Wear appropriate protective clothing, gloves, eye protection and
respiratory equipment.
W A R N I N G
Material can escape uncontrollably with high pressure and
penetrate the body
Death or serious injury and amputations can result.
Before starting maintenance and repair work, disconnect the system
into which the atomizer is built, from any power supply and secure any
form of energy source against reconnection.
Pos: 45 /INP/ Bell2/07_02 Reinigungsmittel @ 57\mod_1503998224710_20.docx @ 620145 @ 23 @ 1
7.2
Cleaning agents
Cleaning agents (ATEX explosion group IIA):
- n-Propanol or Iso-Propanol
Only use moist cloth.
C A U T I O N
Danger from explosive atmospheres
Flammable cleaning agents may explode in the painting booth.
Nonflammable cleaning agents are preferred.
Flammable cleaning agents should be used only if after shutdown of
the high voltage supply all parts conducting high voltage have been
discharged down to a discharge energy of less than 0.24mJ.
The electrically conductive parts of the atomizer must always be
electrically interconnected.