Configuration
Technical Manual
96
V28 - 08/2019
Electronic safe lock
ð
The Device Manager displays the number of all connected devices of the safe lock sys-
tem.
3.
Press the Right arrow key to select the desired device.
ð
The selected devices will be displayed.
ð
Up to 10 connected slave locks will be displayed.
4.
Press the ENTER key to confirm the setting.
15.1.9.2.1
Entering the lock parameters and testing the bus system
There are 2 options:
•
Checking the lock parameters by selecting a desired lock from the lock list
•
Conducting a bus system test of the safe lock system
Any counter number over 040 is a good result of a bus system test.
There is a connection to the tested device.
If the counter numbers are between 000 and 040 it is recommended to check the wiring.
The Device Manager of the master lock displays the number of all connected devices of the
safe lock system.
The Device Manager of the slave locks displays the number 002 (the respective slave lock and
input unit).
Authorization: Master Code
1.
Select the submenu DEVICE.