Functionality
Technical Manual
34
V28 - 08/2019
Electronic safe lock
The lock is currently waiting for the Non-Return Time Delay (NRTD) to elapse.
It is not possible to open the lock during that time, unless it was configured to override with
OTM code.
It is possible to use the INFO/ESC key to check the battery status and the last closed seal.
It is possible to configure different time delays for the code groups.
It is possible to set the Time Delay to "count down", "count up" or "do not count".
Synchronization (OTM)
The lock is not synchronized with AS274 server management software any more.
It is not possible to open the lock with OTM codes.
AS280-INSW must be applied to synchronize the lock again.
Opening Time Delay (OTM)
In OTM, the waiting period is not displayed during an Opening Time Delay.
Opening Time Delay (Bank Mode)
After entering a valid code to open the lock, the set Time Delay starts counting.
The remaining time is displayed.
Every 60 seconds a beep signal sounds.
After the counter has elapsed, the end of the Time Delay is indicated with another beep sig-
nal.
The Courier Code overrides a Time Delay, if not otherwise defined.
Confirmation after elapsed Time Delay (Bank Mode)
After the Time Delay has elapsed, a valid code must be entered as confirmation within a set
time period .
It is possible to enter 2 different valid codes before and after the Time Delay.
The remaining time window is displayed to enter the code.
After entering the Courier Code, the CONF display is shown.
If the Courier Code opens the lock, but skips Time Delay, the opening procedure will start dur-
ing the countdown.
Every 60 seconds a beep signal sounds.
If the code is not confirmed, the lock will return automatically to the closed status once the
counter reached 00:00.
By pressing the DEL key, the lock automatically returns to the LOCKED status.
If the Dual Mode is activated, 2 codes must be entered as confirmation, the sequence is irrele-
vant.
The codes must comply with the settings made via AS284-USBW or AS284- NETW program-
ming software: „any code“, „same code group“ or „different code group“.