Configuration
Technical Manual
90
V28 - 08/2019
Electronic safe lock
15.1.7.8
Setting Time Delay in OTM
Submenu DELAY cit
Authorization: Master Code or Manager Code
Ex factory the Time Delay in OTM is set to 0 minutes.
It is only possible to define minutes for the Time Delay.
It is not possible to define seconds.
The maximum duration of a Time Delay is limited to 99 minutes.
If a Courier Code is entered, the lock will open without Time Delay.
Once a valid code was entered in OTM, the lock only opens after the set Time Delay has
elapsed.
It is possible to set a Time Delay between 0 (no Time Delay) and 99 minutes .
1.
Select the submenu DELAY cit.
2.
Press the ENTER key.
ð
The currently set Time Delay will be displayed.
3.
Use the LEFT or RIGHT arrow key to set the desired Time Delay (setting from 00:00 (de-
activated, no Time Delay) to 99:00 minutes).
4.
Press the ENTER key.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the setting.
15.1.7.9
Configuring Opening Time Delay for duress alarm in OTM
Submenu DURESS cit
Authorization: Master Code
Ex factory the Time Delay for duress alarm in OTM is set to 99 minutes.
It is only possible to define minutes for the Time Delay.
It is not possible to define seconds.
Once a Duress Code is entered in OTM, the lock will open after the Opening Time Delay for
duress alarm has elapsed.
1.
Select the submenu DURESS cit.
2.
Press the ENTER key.
ð
The currently set Opening Time Delay for duress alarm will be displayed (hours:min-
utes).