Functionality
Technical Manual
35
V28 - 08/2019
Electronic safe lock
Entering second code - Dual Mode activated (Bank Mode)
If the Dual Mode is activated, 2 codes must be entered to open the lock.
The message shown on the display prompts the user to enter a second code.
Master Code and Courier Code override the Dual Mode in Bank Mode.
It is possible to open the lock without any additional code, if not otherwise defined.
Penalty after wrong tries (Bank Mode and OTM)
After having entered 4 times an incorrect code, a time penalty of 5 minutes is initiated.
During this time period it is not possible to enter a code, neither to bypass nor to cancel the
procedure.
The remaining penalty time is displayed.
Remote Disabling (Bank Mode and OTM)
It is possible to deactivate the local opening of the lock by a remote disabling signal.
There are 3 options to deactivate the lock opening:
1
By a constant input signal
2
Via AS284-USBW or AS284-NETW programming software or
3
by entering the User Codes 48 or 49, if the codes were set and if User Codes 48 and 49 are
configured for lock enabling or disabling.
The status message RMT-DIS is displayed when Remote Disabling is activated.
During that time the lock is closed.
Pay attentiion that User Code 49 was set, otherwise there will be a high risk of a lock-out.
In case of a failure caused by a device (a broken alarm interface or an alarm interface without
power) transmitting an input signal, the Master Code is able to override Remote Disabling to
prevent a total lock-out when the external signal fails.
Remote Enabling (Bank Mode and OTM)
It is possible to activate a deactivated the lock via an external input signal to enter an opening
code.
When Remote Enabling is activated, this status message will be displayed when the code win-
dow is open.
Remote Enabling is activated via an input impulse of at least 1 second.
Remote Enabling is deactivated after a successful opening or closing procedure.
Identification with denied code (Bank Mode)