Setting Freeze On
To guarantee that the selected lock remains lock -1- (master lock), it is possible to set the
function Freeze for a short moment to ON and then switch to Freeze OFF. The selected lock
will be set as the master lock and even after a power interruption remains the master lock.
Locks with lower serial numbers than the master lock will be added to the lock list as slave
locks.
Lock -1- is the master lock. When the function Freeze ON is activated, no further locks or
eBoxes will be added to the lock list. The error message ERROR -16- will be displayed when a
new lock is added.
A paired eBox will remain paired even after a power interruption. If a further eBox is con-
nected, this eBox will not be paired with lock -1-.
The lock -1- ignores the inputs of the further eBox. When calling the Device Manager, this
eBox is marked with an exclamation mark.
Authorization: Master Code
1.
Select the submenu FREEZE.
2.
Press the ENTER key.
3.
Select ON by using the LEFT or RIGHT arrow key.
4.
Press the ENTER key to confirm the setting.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.