Installation
Technical Manual
68
V28 - 08/2019
Electronic safe lock
It is possible to assign functions of inputs and outputs via AS284-USBW or AS284-NETW pro-
gramming software.
2
4
6
8
10
12
16
14
18
20
1
3
5
7
9
11
15
13
17
19
O
U
T
3B
O
U
T
4B
O
U
T
5B
O
U
T
6B
O
U
T
7B
IN
3
IN
5
IN
7
P
ow
er s
u
ppl
y
G
N
D
O
U
T
3A
O
U
T
4A
O
U
T
5A
O
U
T
6A
O
U
T
7A
IN
4
IN
6
G
N
D
G
N
D
G
N
D
7 mm
Terminal
Description
Unit
18/20
Power supply
9 ... 26VDC / 700 ... 200mA
1/2
Output 3
Factory setting: not assigned
Contact properties
Switching voltage:
24VAC
Load current:
0.4A at 25°C
0.3A at 50 °C
Internal output impedance:
maximum 2Ohm
Relay with potential-free working
contacts
(NO normally open)
3/4
Output 4
Factory setting: not assigned
5/6
Output 5
Factory setting: not assigned
7/8
Output 6
Factory setting:: not assigned
9/10
Output 7
Set for "external power"
12/GND
Input 3
Factory setting: not assigned
Internal input impedance:
min. 4kOhm
Input switch impedance:
max. 10kOhm
9 ... 18VDC (min. 5mA)
11/GND
Input 4
Factory setting: not assigned
14/GND
Input 5
Factory setting: not assigned
13/GND
Input 6
Factory setting: not assigned
16/GND
Input 7
Factory setting: not assigned
Keep in mind that the VdS label becomes void when connecting the network cable to the RJ45
socket of the eBox.
X3
RJ45
X4
Socket
Description
Remarks