53
Single Trigger Setpoint Configuration Summary
If you have followed each of the examples above you have created four output functions
based upon one threshold weight value. As you change the threshold 1 weight each of
the four functions above will be affected. Although simple, these configurations are most
commonly used. Keep reading for more complex operations.
Multi Trigger Setpoint Configuration
Multi trigger setpoint configurations create a robust setpoint that can have intelligence
beyond evaluating the displayed weight versus the weight threshold values. The
following examples build upon those described above.
Stable Over Setpoint
Building on the first Over Setpoint example, it is possible to have a setpoint active only
when stable.
CONFIG SET POINT = out 1
CONFIG OUTPUT CH = hI
CONFIG THRESH 1 = ovEr
CONFIG STABLE = StAbLE
Conversely, the setpoint can be active only when in the scale is in motion by setting
CONFIG STABLE = not.
Checkweigh Setpoint
The Over and Under setpoints above can be programmed as one setpoint using multiple
triggers. Setpoint 1 will be active when under weight threshold 1 and above weight
threshold 2 i.e. active in under and over.
CONFIG SET POINT = out 1
CONFIG OUTPUT CH = Lo
CONFIG THRESH 1 = ovEr
CONFIG THRESH 2 = undEr
If CONFIG OUTPUT CH = hI, setpoint 1 will be active when the weight is between
weight threshold 1 and weight threshold 2 i.e. active in the accept range.
Содержание GuardianXL
Страница 2: ...1...
Страница 8: ...7...
Страница 16: ...15...
Страница 18: ...17 Figure 3 1 Motherboard Load Cell Connection and Jumper Location...
Страница 22: ...21...
Страница 38: ...37 REMOVE THIS PAGE AND REPLACE WITH FIG4 7 PDF PRINT B SIZE Figure 4 7 Setup Mode Menu...
Страница 39: ...38...
Страница 55: ...54...
Страница 84: ...83...
Страница 86: ...85 Figure A 1 Indicator Dimensions Dimension A Standard GuardianXL 6 0 GuardianXL with Relay Option 6 5...