CLEAR
The CLEAR pushbutton is used to cancel any digital entry from the keypad. Pressing
CLEAR when the secondary display reads “ENTRY” will return the scale to the weigh
mode from a digital entry mode.
F1, F2 Programmable Pushbuttons
These pushbuttons can be programmed as an output or function trigger and also act as
batch controls while in the batch mode. See Chapter 4, Setpoint Output and I/O Function
Parameters for details. See Chapter 7 for batch mode information.
MENU
The MENU pushbutton allows access to tare recall, and general configuration of the
GuardianXL
including: setpoints, preacts, accumulators, RS-232 port, date/time and
calibration access. Pressing MENU, then a shortcut pushbutton on the numeric keypad
accesses these configuration features and the non-calibration menu. There are nine
shortcut pushbuttons on the numeric keypad. Each shortcut pushbutton has an
abbreviated feature name accompanying the number on a numeric pushbutton. Each of
these shortcut features is described below. To avoid accidental entry into these features,
access can be eliminated through the use of a pass code. See Chapter 4 to learn about the
features briefly described below in detail.
Programming and Recalling Setpoint & Preact Weight Values
(MENU – SETPOINT)
The
GuardianXL
has four Setpoints and four Preacts. To access the Setpoint or Preact
weight values, press MENU, then 1 (SP) on the numeric keypad. This key sequence
places the
GuardianXL
into the recall mode. The primary display will show the stored
weight value and the polarity. The secondary display will show “RECALL SP 1” when in
the recall Setpoint mode or “RECALL PREACT 1” for the recall Preact mode. Press
numbers 1, 2, 3 or 4 on the numeric keypad once, to recall the respective setpoint value.
Press any of the same numeric key twice will recall the respective Preact value. When
review of the Setpoint or Preact values is complete, press CLEAR to exit the recall mode.
To program a Setpoint or Preact weight value, simply enter the weight value using the
keypad. This places the
GuardianXL
into the “ENTRY” mode and the weight value is
echoed to the primary display. Use the UNITS key only to toggle the polarity of the
setpoint weight value. If an error is made when entering the weight, press CLEAR to exit
the entry mode. When the number is correctly displayed press MENU and the secondary
display will read “SETPOINT ENTRY” and ”SELECT 1,2,3,4,M”. Press the number of
the setpoint (1, 2, 3 or 4) you want to save the current displayed weight. Press the MENU
to enter the Preact entry mode, the secondary display will read “PREACT ENTRY” and “
SELECT 1,2,3,4,M” Press the number of the Preact (1, 2, 3 or 4) you want to save the
current displayed weight.
After the value is saved the scale will return to the weigh mode. Setpoint and Preact
configuration is covered in detail in Chapter 4 and 6.
Содержание GuardianXL
Страница 2: ...1...
Страница 8: ...7...
Страница 16: ...15...
Страница 18: ...17 Figure 3 1 Motherboard Load Cell Connection and Jumper Location...
Страница 22: ...21...
Страница 38: ...37 REMOVE THIS PAGE AND REPLACE WITH FIG4 7 PDF PRINT B SIZE Figure 4 7 Setup Mode Menu...
Страница 39: ...38...
Страница 55: ...54...
Страница 84: ...83...
Страница 86: ...85 Figure A 1 Indicator Dimensions Dimension A Standard GuardianXL 6 0 GuardianXL with Relay Option 6 5...