A3-AG/N3-AG AGRICULTURE KIT 2.0
User Manual
©
2019 DJI All Rights Reserved.
51
Flight Status Indicator Descriptions
LED
Description
Blinking Red, Green and
Yellow Alternatively
The system is running a diagnostic test.
×
4
Blinking Yellow Four Times
The system is warming up.
Blinking Green Slowly
P-mode (Positioning)
Blinking Yellow Slowly
A-mode (Attitude)
Blinking Green Rapidly for 1.5
seconds
Home Point is set successfully
Blinking Yellow Rapidly
Remote controller signal lost
×
3
Blinking Yellow Three Times
Airframe vibration is abnormal, or yaw axis
control is abnormal (for example, the motor
is not properly installed, etc.), or the center of
gravity offset is too large (roll / pitch axis offset
is large)
Blinking Red Slowly
Low voltage warning
Blinking Red Rapidly
Critically low voltage warning
Blinking Red Very Slowly for 5
seconds
The aircraft is in a no-fly zone.
Blinking Red Rapidly for 0.6
second when performing CSC
Large IMU bias or IMU initialization
——
Solid Red
Critial error. Please contact with DJI Support.
Blinking Red and Yellow
Alternatively
Compass calibration required
Water Pump
Operating Voltage
15 V
Operating Current
0 - 2 A
Max Power
30 W
Max Pressure
0.4 MPa
Dimensions
79 mm × 65 mm × 64 mm
Outlet
Inner Diameter: 4.2 mm; Thread: G1/8