23
6. Safety devices for hose rupture
All the load-bearing cylinders are equipped with valves for rupture or leak in the hydraulic
system, which prevent the load from falling.
Outrigger cylinders
Lock valves
Prevent the inching of the
outriggers in either direction.
Lifting cylinder of the boom
Load regulation valve
Prevents the load from falling
down.
Telescope cylinder
Load regulation valve
Prevents the inching of the
telescopic boom in either
direction.
Levelling system
Load regulation valves
Prevents the inclination of the
platform in either direction.
7. Emergency stop buttons
Depressing the emergency stop button, stops all the movements immediately and turns off
the power unit. The button can be found at each control station. Once the button has been
depressed, only the emergency descent functions remain operational.
The emergency stop button locks in the lower position, and it must be released before
starting the power unit.
If the unit does not start, make sure that the emergency descent button is not in the lower
position at any of the control stations.
Содержание DINO 120T
Страница 2: ......
Страница 3: ...3 TRANSLATION OF THE ORIGINAL INSTRUCTIONS Valid from serial number 120T 120328 120330 120TB 60001...
Страница 6: ...6 Operating instructions DINO 120T 120TB BLANK...
Страница 11: ...11 2 2 REACH DIAGRAM...
Страница 45: ...45 BLANK...
Страница 50: ...50 Operating instructions DINO 120T 120TB NOTES...
Страница 51: ...51 NOTES...
Страница 55: ...55 7 2 LUBRICATION PLAN 5 8 6 10 6 7 13 4 2 1 11 3 9 12...
Страница 61: ...61 BLANK...
Страница 62: ...62 Operating instructions DINO 120T 120TB BLANK...
Страница 64: ...64 Operating instructions DINO 120T 120TB NOTES...
Страница 65: ...65 NOTES...