The emergency descent system can only be
operated from the ground. If you are on the
platform, call for help to operate the system.
Operation:
1. Retracting the telescope
Open the emergency descent valve for the
telescope by turning the screw 27 clockwise
and retract the telescope completely by
pumping with the hand pump 28.
2. Lowering the boom
Open the emergency descent valve for
the boom by turning the screw 27 counter-
clockwise and lower the boom by pumping
with the hand pump 28.
3. Close the emergency descent valve by
turning the screw 27 to its centre position.
4. The boom can be turned by placing a crank on the worm gear shaft in the opening in the
plastic cover of the turning device.
5.5.4.
In case of malfunction, when even the emergency descent system is not
operational
If not even the emergency system is working, try to warn other personnel present on the site
or call for more help. When help arrives, try to
• restore the power supply required for normal operation of the lift
• resume the lift's normal operation by other means
• rescue the person on the platform by other means
Always check the condition of the emergency descent system battery before putting the lift
into operation (see point “Operating from the chassis control centre”).
Содержание DINO 120T
Страница 2: ......
Страница 3: ...3 TRANSLATION OF THE ORIGINAL INSTRUCTIONS Valid from serial number 120T 120328 120330 120TB 60001...
Страница 6: ...6 Operating instructions DINO 120T 120TB BLANK...
Страница 11: ...11 2 2 REACH DIAGRAM...
Страница 45: ...45 BLANK...
Страница 50: ...50 Operating instructions DINO 120T 120TB NOTES...
Страница 51: ...51 NOTES...
Страница 55: ...55 7 2 LUBRICATION PLAN 5 8 6 10 6 7 13 4 2 1 11 3 9 12...
Страница 61: ...61 BLANK...
Страница 62: ...62 Operating instructions DINO 120T 120TB BLANK...
Страница 64: ...64 Operating instructions DINO 120T 120TB NOTES...
Страница 65: ...65 NOTES...