23.4 DT400 Option #4
Option # 4
sets the throttle ID of your throttle. Each throttle in your LocoNet
system has its own unique ID. We do not recommend changing this ID but if
you choose to do so, the range of values 00-FF (hex) and you must be sure that
every throttle in your system has a unique ID #.
23.5 DT400 Option #F
Option #F
sets the radio frequency used by the throttle when in radio mode.
This setting is x0A. This value is informational only, users are not able to
change this value.
23.6 DT400 Option #6
Option #6
sets the throttle type. All DT400’s are throttle type x44. You should
not change this value.
Table VI: DT400 Throttle Option #3 Set Up Choices
(Continued)
Op#3
Value
Backlight
Brightness
Clock
Format
Recall
Stack
Depth
Tether-
less
Release
x20
Off
12 hour format
16
No
x21
Low intensity
12 hour format
16
No
x22
Medium intensity
12 hour format
16
No
x23
High intensity
12 hour format
16
No
x24
Off
24 hour format
16
No
x25
Low intensity
24 hour format
16
No
x26
Medium intensity
24 hour format
16
No
x27
High intensity
24 hour format
16
No
x28
Off
12 hour format
16
Yes
x29
Low intensity
12 hour format
16
Yes
x2A
Medium intensity
12 hour format
16
Yes
x2B
High intensity
12 hour format
16
Yes
x2C
Off
24 hour format
16
Yes
x2D
Low intensity
24 hour format
16
Yes
x2E
Medium intensity
24 hour format
16
Yes
x2F
High intensity
24 hour format
16
Yes
80