5–16
SF3x Storage Enclosure FRU Replacement
Example 5–5
(Continued)
PARAMS Dialog Restoring Disk ISE
Parameters
PARAMS> SHOW FORCEUNI
Parameter
Current
Default
Type
Radix
--------- ----------------
-----------------
---------
-----
FORCEUNI
1
1
Boolean
0/1
U
PARAMS> SET FORCEUNI 0
NOTE:
Verify the correct parameter settings before writing. Use the SHOW command.
PARAMS> WRITE
NOTE:
BEFORE RESPONDING TO THE FOLLOWING QUESTION, SET THE MSCP SWITCH
TO THE OFF OR OUT POSITION.
Changes require controller initialization, ok? [Y/(N)] Y
Initializing...
NOTE:
It takes approximately 1 minute before the following message prints.
%HSCPAD-S-REMPGMEND, Remote program terminated - message number 3.
%HSCPAD-S-END, Control returned to node CLOUDF
$
WARNING
If you did not put the MSCP switch in the enable position before
allowing the controller to initialize, you
must
do so before
continuing to the next section.
Failure to put the MSCP switch in the enable position will result
in the loss of VMS communication with this disk ISE at the next
power-up.
Содержание EK-SFXXS-SG-003
Страница 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Страница 10: ......
Страница 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 59: ...DECarray FRU Removal and Replacement 4 3 Figure 4 1 Removing DECarray Door DOOR HINGE S H R X 0 0 1 2 9 1 ...
Страница 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Страница 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Страница 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Страница 176: ......
Страница 180: ......
Страница 220: ......
Страница 224: ......