SF7x Storage Enclosure FRU Replacement
6–45
6.7.2 Replacing the OCP to TTM Cable
Use the following procedure to remove and replace the OCP to TTM cable
(PN 17–02551–01):
1. At the system console, dismount
all
the ISEs on that bus.
2. Access the front of the storage enclosure by opening the cabinet door.
3. Take the disk ISEs in the storage enclosure off-line:
a. Press and release all Ready buttons on the OCP (Figure 6–2).
Wait for the Ready LEDs to go out.
b. At the front of the storage enclosure, set the drive dc power
switches to
off
(Figure 6–2). The switch element LEDs should go
out to indicate that power has been removed from the disk ISE. If
any LED does not go out, suspect a faulty switch.
CAUTION
Wear an ESD grounding strap at all times while handling the
storage enclosure or any of its FRUs.
4. Remove the OCP—grasp it firmly and pull it straight out. Do not pry;
the panel comes free with a straight pull.
5. Loosen the four captive hex-head screws in each corner of the storage
enclosure.
6. Push the inner assembly out of the enclosure until it engages the
latch.
WARNING
Do not extend the storage enclosure past the first mechanical
stop.
Содержание EK-SFXXS-SG-003
Страница 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Страница 10: ......
Страница 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 59: ...DECarray FRU Removal and Replacement 4 3 Figure 4 1 Removing DECarray Door DOOR HINGE S H R X 0 0 1 2 9 1 ...
Страница 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Страница 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Страница 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Страница 176: ......
Страница 180: ......
Страница 220: ......
Страница 224: ......