5–42
SF3x Storage Enclosure FRU Replacement
5.9.2 From the Front of the Storage Array
Perform these steps in the order presented.
1. Ensure that the ac power switch at the rear of the enclosure is on.
2. Listen for the fan spinning. If the fan is
not
spinning, press the ac
power switch to the off position and see Chapter 3.
3. At the front of the enclosure, turn on the drive dc power switch for
each disk ISE.
4. Check power to the disk ISE by the green LED in the drive dc power
switch lights. If the green LED does not light, see Chapter 3.
NOTE
The rear six drives start immediately, while the front six
drives start after a 15 second delay.
NOTE
Setting a drive dc power switch to
on
starts the associated
drive motor.
5. Press the Ready button on the OCP for each desired disk ISE. When
the Ready LED comes on, the disk ISE has completed its internal
diagnostics and is ready for operation. If the Fault LED comes on, see
Section 5.1 for the procedure to repair or replace the disk ISE.
Perform the procedures in Section 5.1.3 if a disk ISE has been repaired or
replaced.
REMEMBER
If the host system(s) has been powered down and ac power
removed, apply ac power to the system(s) and power it back
up.
Содержание EK-SFXXS-SG-003
Страница 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Страница 10: ......
Страница 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 59: ...DECarray FRU Removal and Replacement 4 3 Figure 4 1 Removing DECarray Door DOOR HINGE S H R X 0 0 1 2 9 1 ...
Страница 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Страница 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Страница 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Страница 176: ......
Страница 180: ......
Страница 220: ......
Страница 224: ......