Install the new transition-termination module.
1. Align the new TTM with the nylon posts (Figure 6–12).
2. Set the small black jumper on the TTM to the same bus mode
operation as the one replaced.
3. While facing the front of the storage enclosure, connect all the cables
to the new TTM.
a. Connect the power cable to J1, right-rear of the TTM.
b. Connect the OCP cable to J11, front of the TTM.
c. Connect the fan cable to J6, left-rear of the TTM.
d. Connect the OCP cables as follows:
Left-rear disk ISE, J8 (left-rear of the TTM)
Left-front disk ISE, J10 (left-front of the TTM)
Right-front disk ISE, J9 (right-front of the TTM)
Right-rear disk ISE, J7 (right-rear of the TTM)
e. Connect the left DSSI (50-pin) cable to J5 for through-bus mode or
to J3 for split-bus mode.
f. Connect the right DSSI (50-pin) cable to J4 for through-bus mode
or to J2 for split-bus mode.
4. Slide the inner assembly back into the extrusion tube. Secure the
front panel captive screws. Do not use excessive force as it may strip
the threads in the extrusion tube.
5. Replace the OCP by aligning the OCP connector pins with the TTM
clip fasteners on the transition-termination module. Push, do not
force, the OCP into the fasteners by applying equal pressure to both
sides.
NOTE
Be sure to fold and position the excess cables to prevent
pinching.
6. Move to the back of the enclosure and reposition the DSSI
interconnect cables as needed at the rear bulkhead of the enclosure.
7. Restore the enclosure to service, and run the checkout procedure in
Section 6.8.2.
Содержание EK-SFXXS-SG-003
Страница 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Страница 10: ......
Страница 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 59: ...DECarray FRU Removal and Replacement 4 3 Figure 4 1 Removing DECarray Door DOOR HINGE S H R X 0 0 1 2 9 1 ...
Страница 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Страница 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Страница 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Страница 176: ......
Страница 180: ......
Страница 220: ......
Страница 224: ......