6–34
SF7x Storage Enclosure FRU Replacement
Install the new fan assembly (Figure 6–11).
1. Orient the fan assembly with the fan motor facing the front of
the enclosure and with the fan cable exiting on the left top of the
assembly.
2. Slide the fan assembly in and gently tighten the captive screws, while
avoiding any internal DSSI cables.
3. Reinstall the fan connector J6 at transition-termination module.
CAUTION
Assure that no internal cables have been trapped or pinched
by the fan assembly.
4. Slide the inner assembly back into the extrusion tube. Secure the
front panel captive screws. Do not use excessive force as it may strip
the threads in the extrusion tube.
5. Replace the OCP by aligning the OCP connector pins with the TTM
clip fasteners on the transition-termination module. Push, do not
force, the OCP into the fasteners by applying equal pressure to both
sides.
6. Move to the back of the enclosure and reposition the DSSI
interconnect cables as needed at the rear bulkhead of the enclosure.
7. Turn on the enclosure with the ac power switch at the rear of the
power supply.
8. Restore the enclosure to service, and run the checkout procedure in
Section 6.8.2.
Содержание EK-SFXXS-SG-003
Страница 1: ...DECarray Service Guide EK SFXXS SG 003 Digital Equipment Corporation ...
Страница 10: ......
Страница 18: ...1 8 Introduction Figure 1 3 SF7x Series Storage Enclosure SHR_X1123C_89 ...
Страница 24: ......
Страница 44: ......
Страница 56: ......
Страница 59: ...DECarray FRU Removal and Replacement 4 3 Figure 4 1 Removing DECarray Door DOOR HINGE S H R X 0 0 1 2 9 1 ...
Страница 168: ...6 60 SF7x Storage Enclosure FRU Replacement Figure 6 18 Enclosure Internal DSSI Cables ...
Страница 169: ...SF7x Storage Enclosure FRU Replacement 6 61 Figure 6 19 Enclosure Internal DSSI Cables cont ...
Страница 170: ...6 62 SF7x Storage Enclosure FRU Replacement Figure 6 20 Enclosure Internal DSSI Cables cont ...
Страница 176: ......
Страница 180: ......
Страница 220: ......
Страница 224: ......