B–16
DECarray Cabling Information
B.2 DSSI VAXcluster Configurations
This section contains cabling information for DECarray variations in the
DSSI VAXcluster configuration.
Note the following:
• DSSI bus termination is supplied by the KFMSA modules installed in
each host system.
• All KFMSA modules installed in each host system must be set to the
same DSSI ID.
• All SF7x storage enclosures operate in through-bus mode.